Downloads
| Version | Changes |
|---|---|
| 3/28/2026 | Bug fix IEC 60870-5-103: IED General Interrogation response now scoped to the requested slave address only — previously all configured addresses were returned regardless of which slave was interrogated Bug fix IEC 60870-5-101: IED now discards frames with invalid checksum instead of processing them Bug fix IEC 60870-5-101: IED now echoes the correct QOI byte in GI actcon/actterm/deactcon responses Bug fix IEC 60870-5-101: IED counter interrogation deactivation (COT=8) now receives a deactcon instead of being rejected Bug fix IEC 60870-5-101: maximum variable-frame payload length corrected from 253 to 255 bytes Bug fix IEC 60870-5-102: IED counter interrogation data now sent with COT=37 instead of COT=20 Bug fix IEC 60870-5-102: IED actterm for CI command types 120–123 now correctly applies to all integrated-total families Bug fix IEC 60870-5-102: Control Center now recognizes actterm for command ASDU types 104–123 Bug fix Communication interfaces: TCP server now disposes IEC 104 session context on client disconnect, preventing resource leaks Bug fix Address Tracking: deleting a slave now fires correct removal events for each child address Change IEC 60870-5-101: IED dirty-address tracking is now per-connection so multiple simultaneous sessions no longer interfere Change IEC 60870-5-104: STOPDT handshake is now initiated and awaited before closing connection, preventing loss of in-flight data Change IEC 60870-5-104: IED dirty-address tracking is now per-connection; GI/CI status fields show live values Change IEC 60870-5-104: IED logs CP56Time2a timestamps from timed command variants to the comment stream Change IEC 60870-5-104: settings now warn when w exceeds ⅔ of k, as recommended by the standard Change ABB RP570: IED dirty-address tracking is now per-connection New Address Tracking: snapshot — take a point-in-time snapshot of all tracked addresses and compare live data against it, with color-coded highlighting for changed rows and phantom entries for removed addresses New Address Tracking: timestamp sanity check — timestamp column cells are highlighted when the protocol timestamp differs from the received time by more than a configurable threshold New Events: timestamp sanity check with configurable threshold highlighting New Alarms: timestamp sanity check with configurable threshold highlighting |
v3.2.9581.41217 3/26/2026 |
Change If Quality (Flags) changes will also send to Events New Events can be set as suppressed from Events window New Alarms can be set as suppressed from Alarms window New New setting to disable Events when Quality/Timestamp changes |
v3.1.9567.35319 3/12/2026 |
Bug fix PCAP import/export could leak file handles and produced unnecessary memory spikes for gzip files Bug fix Packet-builder queue could accept null or empty commands silently Bug fix IEC 60870-5-101: Control Center was not using the configured link address when sending requests Bug fix IEC 60870-5-101: Responses were accepted regardless of link address — incoming frames are now filtered by the configured link address Bug fix IEC 60870-5-101: IED mode did not properly execute many control commands — single, double, regulating-step, bitstring, and setpoint commands now behave correctly and return the expected confirmations Bug fix IEC 60870-5-101: Link handling mixed up two reply codes during polling — communication state and "no data" responses are now interpreted correctly, improving poll stability Bug fix IEC 60870-5-101: Protection-event ASDUs M_EP_TD_1, M_EP_TE_1, M_EP_TF_1 showed incorrect timestamps — CP56 time is now formatted correctly Bug fix IEC 60870-5-101: CP56 time parsing could throw for invalid date components — invalid dates now return a safe fallback instead of crashing Bug fix IEC 60870-5-101: FT1.2 payload limit of 253 bytes was not enforced — oversized frames are now rejected in CC, IED, and the command builder Bug fix IEC 60870-5-101: Link address width was handled inconsistently across the code — now normalized everywhere Bug fix IEC 60870-5-102: IED mode only sent an ACK instead of actual counter data — IED now builds and returns real IEC102 data ASDUs from tracking objects Bug fix IEC 60870-5-102: Sunday was encoded as 0 in CP56 day-of-week — corrected to 7 per protocol specification Bug fix IEC 60870-5-102: COT negative and test flags were not retained during packet parsing Bug fix IEC 60870-5-102: Parser could go out of range for ASDU types above the table limit Bug fix IEC 60870-5-103: Multi-object ASDUs with SQ=0 (sequential) were not parsed correctly — INF now increments for sequential objects and per-object FUN/INF pairs are read for SQ=1 (individually addressed) Bug fix IEC 60870-5-103: IEC103 tracking and tracer-creation used inconsistent address representations — now uses a unified packed FUN/INF address throughout Bug fix IEC 60870-5-103: IED mode only sent ACK instead of real data — IED now builds and returns actual IEC103 variable-frame ASDUs from tracking objects Bug fix IEC 60870-5-103: Frames were not checksum-validated before dispatch in IED mode Bug fix IEC 60870-5-103: Sunday was encoded as 0 in time-sync commands — corrected to 7 Bug fix IEC 60870-5-104: 15-bit sequence number wrap was not handled correctly — sequence numbers now wrap at 0x7FFF as required Bug fix IEC 60870-5-104: TESTFR state was lost after a TESTFR exchange — previous state is now saved and restored correctly Bug fix IEC 60870-5-104: STARTDT used t1 timeout instead of t0 Bug fix IEC 60870-5-104: W-window check used simple linear comparison, which failed across 15-bit wrap boundaries — now uses modulo-safe arithmetic Bug fix IEC 60870-5-104: U-format frames (TESTFR, STARTDT, STOPDT) were incorrectly modified by FixSeqNo Bug fix IEC 60870-5-104: Fragmented TCP frames were re-read from the wrong source buffer during reassembly Bug fix IEC 60870-5-104: Execute-without-select was silently ignored for most command types — now returns a proper negative actcon Bug fix IEC 60870-5-104: Invalid DCO (double command) and RCO (regulating step) values 0 and 3 were accepted — now rejected with negative confirmation Bug fix IEC 60870-5-104: GI and CI requests used hardcoded originator address 0 instead of the configured value Bug fix IEC 60870-5-104: Command builder used hardcoded originator address 0 Bug fix IEC 60870-5-104: S-format APCI was constructed incorrectly in the packet builder Bug fix IEC 60870-5-104: Graph 1 help boxes used the Graph 3 color scheme Bug fix IEC 60870-5-104: Signed BCR (binary counter reading) values were displayed as unsigned Bug fix ABB RP570: IED mode decoded frames with its own offset logic instead of using the shared parser — IED now uses the canonical RP570 decode path Bug fix ABB RP570: CC response detection read from the wrong byte index (RTU byte instead of FCODE byte) Bug fix ABB RP570: GOM tracking objects were created with the wrong type (SPM instead of GOM) Bug fix ABB RP570: SPM/GOM IED emulation sent no reply when the target address was not found — now returns NXR Bug fix ABB RP570: Tracking and text analysis could crash on truncated payloads for AVM, DVM, PCM, DVL, PCT, SPM, GOM, ERMD, ERMI, ERMC, CBXC, EXC, IHC — bounds checks added throughout Bug fix ABB RP570: Command builder silently truncated object numbers above the 11-bit limit — now throws an explicit error Bug fix ABB RP570: IDM split menu visibility was based on fragile name-string parsing — now uses type-based check Bug fix ABB SPA-bus: SPA reply sending was broken by the shared framework — IED and CC replies are now correctly transmitted Bug fix ABB SPA-bus: Request-state tracking used a fixed 1000-entry array — replaced with a dictionary to handle any slave identifier safely Bug fix ABB SPA-bus: Non-numeric or out-of-range slave identifiers could cause an exception during tracking Bug fix ABB SPA-bus: Request state was not cleared when re-opening a session — stale entries from a previous session no longer affect the next one Change IEC 60870-5-102: Incoming frames were not checksum-validated in IED mode Change IEC 60870-5-103: Type 1 and Type 2 event values now include Relative Event Time (RET) and Fault Number (FAN) where present Change IEC 60870-5-103: IEC103 custom columns now have correct labels matching the displayed data (Address, Flow, FC, ASDU, COT, FUN, INF) Change IEC 60870-5-104: Value text added for clock sync (C_CS_NA_1), delay acquisition (C_CD_NA_1), and parameter ASDUs Change ABB RP570: Command-response matching for CBR is now object-aware; EXR/NXR fallback uses oldest pending command by time Change ABB RP570: ERMA, ERMD, ERMI text output now includes sequence number and time-quality information New IEC 60870-5-101: IED mode now responds to counter interrogation (C_CI_NA_1), read (C_RD_NA_1), clock synchronization (C_CS_NA_1), test (C_TS_NA_1), and delay acquisition (C_CD_NA_1) commands New IEC 60870-5-101: CC now logs when the slave reports link service not functioning (FC=14) or not implemented (FC=15) New IEC 60870-5-102: Counter interrogation now covers the full IEC102 CI command family (types 104–123) instead of only type 104 New IEC 60870-5-102: Single-point read workflow added: CC and IED now support C_SP_NA_2 and C_SP_NB_2 New IEC 60870-5-102: Data Flow Control (DFC) is now respected — CC pauses sending when the slave signals busy New IEC 60870-5-102: CP56 timestamps are now extracted and shown for time-tagged IEC102 packets (M_SP_TA_2, M_TI_TA_2) New IEC 60870-5-102: Command builder now selects the correct CI variant and single-point command type based on the tracking object New IEC 60870-5-103: CC now prioritizes Class 1 polling when the slave signals ACD (has Class 1 data available) New IEC 60870-5-103: CC and IED now filter frames by the configured IEC103 link address (broadcast 0xFF is always accepted) New IEC 60870-5-103: Reserved control bit (bit 7) violations in received frames are now rejected New IEC 60870-5-103: Negative confirmation (COT=21) is now logged when the slave rejects a command New IEC 60870-5-104: New configurable settings: Originator Address, Allow Clock Sync, Require Select-Before-Operate (SBO) New IEC 60870-5-104: Preference panel now warns when t2 ≥ t1 or w > k New IEC 60870-5-104: APDU length is now validated (minimum 4, maximum 253 bytes) New IEC 60870-5-104: Clock synchronization (C_CS_NA_1) is now gated by the Allow Clock Sync setting — disabled by default New IEC 60870-5-104: Delay acquisition correction (C_CD_NA_1) is now applied when processing subsequent clock sync commands New IEC 60870-5-104: Select-before-operate redesigned with 30-second SBO timeout and per-address tracking New IEC 60870-5-104: Parameter ASDUs (110–112) and file-transfer types (120–127) now return explicit "unsupported type" negative confirmations New IEC 60870-5-104: Originator address validation: non-zero configured OA rejects mismatching incoming ASDUs New IEC 60870-5-104: GI retry logic: CC retries general interrogation up to 3 times on timeout before proceeding to counter interrogation New IEC 60870-5-104: Row coloring: slave-to-master frames are shown in white, master-to-slave in light gray New IEC 60870-5-104: Control format decoding: I/S/U format is now clearly shown in packet details (e.g., NS=x NR=y, STARTDT.act, TESTFR.con) New IEC 60870-5-104: Protection-event ASDU types (17–19, 38–40) and control types C_TS_NA_1 / C_CD_NA_1 added to the packet table New ABB RP570: IED now rejects frames with invalid checksums before processing New ABB RP570: CC now validates checksums for both fixed and variable frames before updating state New ABB RP570: IED now has explicit response behavior for FTAB and TDC commands New ABB RP570: IED now validates TSI payload length: short payloads receive NXR, valid payloads receive EXR New ABB RP570: SCI rearm now triggers after a configurable inactivity timeout (5 minutes) New ABB RP570: PMRV tracking now decodes individual block/value pairs instead of only a summary event New ABB RP570: Truncated packets now show explicit [TRUNCATED] markers in text analysis instead of risking index overruns New ABB SPA-bus: Incoming SPA frame checksums are now validated; frames with incorrect checksums are flagged; XX checksum bypass is supported |
v3.0.9512.32882 1/16/2026 |
Bug fix Auto-reconnect now works again Change Proper IEC 60870-5-104 implementation for master and slave Change Full support for ABB RP570 protocol, including ERMI Change Performance improvements New IEC 60870-5-101 support for both master and slave, in addition to monitoring New IEC 60870-5-102 support for both master and slave, in addition to monitoring New Full IEC 60870-5-103 support for monitoring, master and slave New New automatic visual indication of events with time gap, to simplify finding new events New New event popup to indicate new events with clear message New Proper warnings if IEC 60870-5-10x messages are wrong or invalid New Mark tested signals as Accepted for easy FAT/SAT testing New Quick sending of Single/Double commands to client from tracking window (context menu) New Change visible columns (right mousebutton on header) |
v2.13.9458.18220 11/23/2025 |
Bug fix Playback function was broken, now working again Change Improved performance for loading SerialMon MON-files Change Updated components New New window for import of RTU560 Excel file, where columns can be selected manually (with preview) |
v2.12.9447.36836 11/12/2025 |
Change Updated components Change Cleanup of deprecated components Change IPv4-scanner: Updated manufacturer MAC-database |
v2.11.9434.28373 10/30/2025 |
New Changes highlighted in grids New Better performance and smaller filesize |
v2.10.9432.38056 10/28/2025 |
Bug fix RP570 PacketBuilder was broken Bug fix Popup menu at grids in main window was not working Bug fix Solved freeze that could happend with a lot of packets Bug fix SerialMon v2.10.9426.35941 did not start. Please re-install. Change Updated components Change Serious improvement in loading files New Show number of addresses in main window status bar New New function to delete addresses in Address Tracker New Filter function for Events/Alarms to show only addresses with a user name/comment |
v2.10.9408.35428 10/4/2025 |
Change Updated components |